COORDINATION OF RECLOSERS AND FUSE CUT-OUTS ON 20 kV MEDIUM VOLTAGE OVERHEAD LINES (SUTM) AT THE EBAN FEEDER OF PT.PLN (PERSERO) ULP KEFAMENANU

Shindi Anjeline Rambu, Frans J Likadja, Almido Ginting

Abstract


The Eban feeder is the longest feeders at PT. PLN (PERSERO) ULP Kefamenanu, with a medium- voltage overhead line length of 60.62 kms. In the distribution system, the Eban feeder is equipped with one Joongwon recloser on the medium-voltage network and 16 Fuse Cut Outs (branch points). This study aims to determine the coordination between the recloser and the Fuse Cut Outs (FCO) on the Eban feeder. The research method used is quantitative descriptive to identify the coordination settings of the recloser and FCO. The test data in this study include recloser settings, FCO ratings, transformer data, load data, CT data, and simulation using Etap 19.0.1. In the event of a short-circuit fault, the Nian recloser will operate first, with a breaking time of 0.521s.

Full Text:

PDF (6-12)

References


Arif, Nurfadilla, Aksan, and Hamdani. 2021. “Analisis Koordinasi Recloser Dan Fco ( Fuse Cut Out ) Pada

Feeder Express Mangkutana Out Kalaena PT . PLN ( Persero ) ULP Tomoni.” Teknik Elektro, no. September:

–56.

Abdul, A. Z. (2017). Proyek Akhir Sampai Ke Ujung Dengan Menggunakan Aplikasi Etap DiPt . Pln

( Persero ) Up3 Semarang Program Diploma Iii . 71-044.M.

Anam, M. (2021). Analisa Koordinasi Recloser Joongwoon JWREC-8A Dengan Fuse CutOut Tipe K untuk Pengamanan Arus lebih. PhD Thesis. Unisnu Jepara.

Ario Putra, and Firdaus. 2017. “Analisa Penggunaan Recloser Untuk Pengaman Arus Lebih Pada Jaringan

Distribusi 20 KV Gardu Induk Garuda Sakti.” Jom FTEKNIK 4 (1): 1–10.

Bahri, M. (2018). Analisa Penempatan Recloser Dan Fuse Cut Out Terhadap Keandalan Sistem Tenaga Listrik

Di Jaringan Distribusi Di PT.PLN (Persero) Rayon Rimo (Doctoral Dissertation).

Galla, Wellem F, Agusthinus S. Sampeallo, and Julian I. Daris. 2020. “Analisis Gangguan Hubung Singkat Pada Saluran Udara 20 KV Di Penyulang Naioni Pt. Pln (Persero) Ulp Kupang Untuk Menentukan Kapasitas Pemutusan Fuse Cut Out Menggunakan Etap 12.6.” Jurnal Media Elektro IX (2): 101–12.

https://doi.org/10.35508/jme.v0i0.3208.

Hasugian, D A P. 2022. “Penempatan Recloser Terhadap Keandalan Sistem Distribusi Di PT. PLN (Persero) Kota Subulussalam Aceh.” Jurnal Ilmiah Mahasiswa Teknik [JIMT] 3 (September): 273–81.

http://jurnalmahasiswa.umsu.ac.id/index.php/jimt/artic le/view/1932.

Iqbal Setiwan. (2017). Analisis Koordinasi Recloser Dan Fuse Cut Out (FCO) Pada Penyulang Apel Di

PT.PLN Rayon Taboali.

Nugroho, Henry, and Iman Setiono. 2021.

“Koordinasi Recloser Dengan FCO( Fuse Cut Out) Sebagai Pengaman Terhadap Gangguan Arus Lebih Pada Penyulang Dengan 1 Fasa Di Gardu Induk Sanggrahan

Magelang.” Seminar Nasional Teknologi Informasi Dan Komunikasi Terapan.

Paembonan, Evan Januar, Ahmad Rizal Sultan, and Sofyan Sofyan. 2021. “Analisis Fuse Cut Out Sebagai

Proteksi Penyulang Tondon Pada Jaringan Distribusi Di PT. PLN (Persero) ULP Rantepao.” Seminar Nasional

Teknik Elektro Dan Informatika (SNTEI), no. September: 74–79. http://repository.poliupg.ac.id/1129/1/FILE

SNTEI 2021_01.pdf.

Pramana, K. A., Manuaba, I. G., & Pemayun, A. G. M (2021). Studi Koordinasi Sistem Peralatan Proteksi

Pada Penyulang Pidada Untuk mendapatkan Setting Pengaman Yang Selektif. Jurnal Spektrum Vol, 8(4).

Priyanto, F., & Putra. (2022). ANALISA KOORDINASI PROTEKSI RECLOSER BATU KAMBING .

Jurnal. Univ. Islam Kalimantan MAB.

Saputra Rahman, A., Diantari, R. A., & Azis, H. (2021). Studi Setting Recloser Sebagai Proteksi Arus

Gangguan Hubung Singkat Pada Penyulang Kaze Di PTT.PLN (Persero) UP3 Cengkareng (Doctoral

Dissertation, Institut Teknologi Pln)

Sitio, N.S., Untoro, A., & Samsurizal, S. (2020). Analisis Setting Koordinasi Recloser Dan Sectionalizer Pada Penyulang Ruko Di Gardu Induk Legok PT.PLN (Persero) UP3 Seprong (Doctoral Dissertation, Instituti

Teknologi Pln).

SPLN D3.026:2017. 2017. “Spesifikasi Fuse Cut Out,”no.xxx.https://id.scribd.com/document/492820433/SPLN-D3-026-2017-Final-Locked.

SPLN 64. (1985). Petunjuk, Pemilihan dan Pengguanaan Fuse Cut Out Pada Sistem Distribusi Tegangan Menengah. Jakarta: PT.PLN,

Wahyu Nugroho, Ramadoni Syahputera, Slamet Suripto. (2021). Analisis Penempatan,Setting Dan Kinerja Recloser Dan Fuse Cut Out Pada Penyulang Pedan 6 PT.PLN (Persero) Area Klaten

Ulumuddin, N W, Hari Purnama, and Supriyanto. 2021. “Pengaruh Distributed Generation Terhadap

Koordinasi Proteksi Recloser Fuse Pada Jaringan IEEE 34 Node Menggunakan ETAP.” Prosiding The 12th

Industrial Research Workshop and National Seminar, 434–39.




DOI: https://doi.org/10.37058/jeee.v7i1.16265